Supported configurations for managed systems with BMC or IMM
Supported versions of IBM Systems Director Agent
Supported configurations for managed systems with RSA-II
Knowledge Article: Hardware License
Knowledge Article: Power Threshold Event
Knowledge Article: ID B00000067: Multiple Chassis Cooling Device failures
Knowledge Article: ID B0000006B: Event log full
Knowledge Article: ID B0000006F: Blade voltage outside of recommended range
Knowledge Article: ID B00000072: POST watchdog triggered
Knowledge Article: ID B00000073: OS watchdog triggered
Knowledge Article: ID B00000077: System boot failed
Knowledge Article: ID B00014033: USB port overcurrent failure
Knowledge Article: ID B00015011: Configurations of Automated FTP problem report.
Knowledge Article: ID B00015050: Service data collection for event
Knowledge Article: ID B0001600A: LAN: Tamper delay triggered. Possible break in attempt.
Knowledge Article: ID B00016015: IP address of primary MM is the same as the IP address of standby MM. Standby network interface is disabled.
Knowledge Article: ID B00016400: Invalid encryption keys detected. Regenerating encryption keys. Verify local login profile configurations
Knowledge Article: ID B00016401: Invalid login profile. Reconfigure the password for user
Knowledge Article: ID B00016402: Invalid login profile. Reconfigure the privacy password for user
Knowledge Article: ID B00016801: Call Home failed
Knowledge Article: ID B0001C482: Chassis ambient over temperature fault
Knowledge Article: ID B0001C500: Management module over temperature.
Knowledge Article: ID B0001C800: System ambient under temperature fault.
Knowledge Article: ID B0001D400: Management module is over recommended temperature.
Knowledge Article: ID B0001D502: Chassis over recommended ambient temperature.
Knowledge Article: ID B0001D800: System under recommended ambient temperature
Knowledge Article: ID B00020000: Failure reading device on system management bus
Knowledge Article: ID B00022001: Blade management bus 1 failed.
Knowledge Article: ID B00022002: Blade management bus 2 failed.
Knowledge Article: ID B00022003: Primary MM real-time clock failed.
Knowledge Article: ID B00022004: Primary MM local management bus failed.
Knowledge Article: ID B00022005: Primary MM primary file system failed.
Knowledge Article: ID B00022006: Primary MM secondary file system failed.
Knowledge Article: ID B00022008: Primary MM Ethernet port 0 failed.
Knowledge Article: ID B00022009: Primary MM external management bus timed out and was reset.
Knowledge Article: ID B0002200A: Primary MM internal ethernet switch failed.
Knowledge Article: ID B00022011: Primary MM USB keyboard/mouse emulation failed.
Knowledge Article: ID B00022012: Primary MM USB mass storage emulation failed.
Knowledge Article: ID B00022015: Standby MM real-time clock failed.
Knowledge Article: ID B00022016: Standby MM local management bus failed.
Knowledge Article: ID B00022017: Standby MM primary file system failed.
Knowledge Article: ID B00022018: Standby MM secondary file system failed.
Knowledge Article: ID B00022019: Standby MM internal I/O expander failed.
Knowledge Article: ID B0002201C: Standby MM ethernet port 0 failed.
Knowledge Article: ID B0002201D: Standby MM internal ethernet switch failed.
Knowledge Article: ID B0002201E: Alternate MM communication failed
Knowledge Article: ID B00022049: BIST blade management bus 1 failed.
Knowledge Article: ID B0002204A: BIST blade management bus 2 failed.
Knowledge Article: ID B00022052: Standby MM primary core failed.
Knowledge Article: ID B00022053: Standby MM backup core failed.
Knowledge Article: ID B00022054: Primary MM USB keyboard/mouse firmware failed.
Knowledge Article: ID B00022055: Primary MM USB mass storage firmware failed.
Knowledge Article: ID B00022058: Primary MM primary core failed.
Knowledge Article: ID B00022059: Primary MM backup core failed.
Knowledge Article: ID B0002205A: Primary MM internal I/O expander failed.
Knowledge Article: ID B00026801: Chassis Cooling Device %d failure
Knowledge Article: ID B00026801: Chassis Cooling Device %d failure
Knowledge Article: ID B00028000: Blade power fault.
Knowledge Article: ID B00028001: Blade power fault.
Knowledge Article: ID B000A2001: Chassis Cooling Device 1 communication failed.
Knowledge Article: ID B000A6001: Chassis Cooling Device %d outside of recommended speed
Knowledge Article: ID B000A7801: Chassis Cooling Device %d outside of recommended speed
Knowledge Article: ID B000AA020: Mismatched chassis cooling devices are not supported.
Knowledge Article: ID B00101000: One or more blades are isolated from the management bus.
Knowledge Article: ID B00101007: Unable to isolate bus fault. Bus was not recovered.
Knowledge Article: ID B0011C501: Management module is over recommended temperature.
Knowledge Article: ID B0011C881: Management module under temperature
Knowledge Article: ID B0011C901: Management module under recommended temperature
Knowledge Article: ID B0011D801: Management module under recommended temperature
Knowledge Article: ID B00216000: Problem communicating with BSMP.
Knowledge Article: ID B00216010: PCI PERR: parity error.
Knowledge Article: ID B00216011: PCI system error.
Knowledge Article: ID B00216012: Uncorrectable bus error.
Knowledge Article: ID B0021601C: FW/BIOS backup ROM corruption. System board failure.
Knowledge Article: ID B0021603E: PCI bus timeout: system error.
Knowledge Article: ID B00217000: Management module external network physical link lost.
Knowledge Article: ID B00217001: Management module external network logical link lost.
Knowledge Article: ID B00222000: Standby MM failure on system management bus, check devices
Knowledge Article: ID B00282005: Configuration of mismatched management modules is not supported.
Knowledge Article: ID B04000000: FW/BIOS ROM corruption detected.
Knowledge Article: ID B04000080: Multiprocessor Expansion Unit board fault.
Knowledge Article: ID B04000300: Power jumper not present.
Knowledge Article: ID B04000381: Blade %d incompatible with chassis.
Knowledge Article: ID B04018000: Blade voltage fault.
Knowledge Article: ID B0401E000: Invalid CPU configuration
Knowledge Article: ID B04200201: CPU %d Fault
Knowledge Article: ID B04204001: CPU %d disabled
Knowledge Article: ID B0421C081: CPU %d over temperature
Knowledge Article: ID B0421C481: CPU %d temperature fault
Knowledge Article: ID B0421D081: CPU %d over temperature
Knowledge Article: ID B0421D401: CPU %d temperature warning
Knowledge Article: ID B0421D501: CPU %d over recommended temperature
Knowledge Article: ID B04300201: CPU %d internal fault
Knowledge Article: ID B04306201: CPU %d halted
Knowledge Article: ID B04401501: Voltage regulator %d over recommended voltage.
Knowledge Article: ID B04401801: Voltage regulator %d under recommended threshold.
Knowledge Article: ID B04428000: Voltage regulator fault.
Knowledge Article: ID B04428001: Voltage regulator %d fault.
Knowledge Article: ID B05200000: Blade memory fault
Knowledge Article: ID B06000000: The real time clock battery in the blade needs service.
Knowledge Article: ID B06002001: Request to release MT failed - MT seized by Management Module -- for
Knowledge Article: ID B06002002: Request to release KVM failed - KVM seized by Management Module -- for
Knowledge Article: ID B06002003: Request to acquire MT denied by Management Module for
Knowledge Article: ID B06002004: Request to acquire KVM denied by Management Module for
Knowledge Article: ID B06016000: I/O board fault
Knowledge Article: ID B06018000: I/O board voltage fault
Knowledge Article: ID B0601A000: I/O board power fault
Knowledge Article: ID B06026080: Critical chassis cooling device failure. Blade powered off.
Knowledge Article: ID B06035500: Blade 5V over recommended voltage
Knowledge Article: ID B06035800: Blade 5V under recommended voltage
Knowledge Article: ID B06035700: Blade 12V over recommended voltage.
Knowledge Article: ID B06037800: Blade 12V under recommended voltage
Knowledge Article: ID B0621C481: BEM temperature fault
Knowledge Article: ID B0621D481: BEM over recommended temperature
Knowledge Article: ID B06500000: PCI Parity Error.
Knowledge Article: ID B06800000: BEM failure
Knowledge Article: ID B06800001: Hard drive %d fault.
Knowledge Article: ID B06802000: Hard drive %d fault.
Knowledge Article: ID B0681C482: System shutoff due to DASD Option temperature.
Knowledge Article: ID B06A2E001: Media Tray 1 temperature is unavailable. Cooling capacity set to maximum.
Knowledge Article: ID B08001400: Blade 1.25V over recommended voltage
Knowledge Article: ID B08001401: Blade 1.2V over recommended voltage
Knowledge Article: ID B08001800: Blade 1.25V under recommended voltage
Knowledge Article: ID B08001801: Blade 1.2V under recommended voltage
Knowledge Article: ID B08006001: Mismatched power modules in power domain
Knowledge Article: ID B08016080: Power controller timeout.
Knowledge Article: ID B08028001: Power module %d is off. DC fault.
Knowledge Article: ID B08028081: Power Module %d failed to power on because of input AC mismatch.
Knowledge Article: ID B08028481: Power module %d is off. AC fault.
Knowledge Article: ID B08031480: Blade 2.5V over recommended voltage
Knowledge Article: ID B08031880: Blade 2.5V under recommended voltage
Knowledge Article: ID B08033480: Blade 3.3V over recommended voltage
Knowledge Article: ID B08033880: Blade 3.3V under recommended voltage
Knowledge Article: ID B08035500: Blade 5V over recommended voltage
Knowledge Article: ID B08035800: Blade 5V under recommended voltage
Knowledge Article: ID B08039480: Blade 1.6V over recommended voltage
Knowledge Article: ID B08039880: Blade 1.6V under recommended voltage
Knowledge Article: ID B08039480: Blade -5V over recommended voltage
Knowledge Article: ID B0803D800: Blade -5V under recommended voltage
Knowledge Article: ID B08041400: Blade 1.5V over recommended voltage
Knowledge Article: ID B08041800: Blade 1.5V under recommended voltage
Knowledge Article: ID B0807B400: Blade 1.8V over recommended voltage
Knowledge Article: ID B0807B800: Blade 1.8V under recommended voltage
Knowledge Article: ID B08100080: Incompatible power controller firmware.
Knowledge Article: ID B08200001: Power module %d communication failure.
Knowledge Article: ID B0821C001: Power module %d has exceeded the warning temperature.
Knowledge Article: ID B0821C080: Blade powered off because power modules exceeded temperature threshold.
Knowledge Article: ID B0821C081: Power module %d temperature fault.
Knowledge Article: ID B0821E001: Power module %d removed
Knowledge Article: ID B08236481: Power module %d over voltage fault
Knowledge Article: ID B08236801: Power module %d under voltage fault
Knowledge Article: ID B08238001: Power module %d 48V over current fault.
Knowledge Article: ID B08238481: Power module %d 48V over voltage fault.
Knowledge Article: ID B08238801: Power module %d 48V under voltage fault
Knowledge Article: ID B08240001: Power module %d PSOC Controller communication failed
Knowledge Article: ID B09025000: Front panel cable is not connected to system board.
Knowledge Article: ID B0A000000: Concurrent KVM card fault detected.
Knowledge Article: ID B0A000280: Uncorrectable memory error
Knowledge Article: ID B0A000281: Uncorrectable memory error detected on DIMM %d
Knowledge Article: ID B0A000400: Correctable memory error logging limit reached
Knowledge Article: ID B0A000401: Correctable memory error logging limit reached on DIMM %d
Knowledge Article: ID B0A000580: Memory disabled
Knowledge Article: ID B0A000581: Memory disabled on DIMM %d
Knowledge Article: ID B0A00AC02: 1.2V standby under recommended voltage
Knowledge Article: ID B0A00BC02: 1.2V standby over recommended voltage
Knowledge Article: ID B0A027000: Insufficient Chassis Cooling to support blade operations. Blades can be shutdown
Knowledge Article: ID B0A027100: Reduced cooling capacity in the chassis. Loss of an additional Chassis Cooling Device will cause blade(s) to shutdown.
Knowledge Article: ID B0A02CC00: I/O board 3.3V under recommended voltage
Knowledge Article: ID B0A02CC01: I/O board 3.3V standby under recommended voltage
Knowledge Article: ID B0A02CC02: 3.3V standby under recommended voltage
Knowledge Article: ID B0A02DC00: I/O board 3.3V standby over recommended voltage
Knowledge Article: ID B0A02DC01: I/O board 3.3V over recommended voltage.
Knowledge Article: ID B0A02DC02: 3.3V standby over recommended voltage
Knowledge Article: ID B0A030C00: I/O board 2.5V under recommended voltage.
Knowledge Article: ID B0A030C01: I/O board 2.5V standby under recommended voltage.
Knowledge Article: ID B0A030C02: 2.5V standby under recommended voltage
Knowledge Article: ID B0A031C00: I/O board 2.5V over recommended voltage.
Knowledge Article: ID B0A031C01: I/O board 2.5V standby over recommended voltage.
Knowledge Article: ID B0A031C02: 2.5V standby over recommended voltage
Knowledge Article: ID B0A034C00: I/O board 5V under recommended voltage.
Knowledge Article: ID B0A034C02: 5V standby under recommended voltage
Knowledge Article: ID B0A035C00: I/O board 5V over recommended voltage.
Knowledge Article: ID B0A035C02: 5V standby over recommended voltage
Knowledge Article: ID B0A036C00: I/O board 12V under recommended voltage.
Knowledge Article: ID B0A036C01: I/O board 12V standby under recommended voltage.
Knowledge Article: ID B0A036C02: 12V standby under recommended voltage
Knowledge Article: ID B0A037C00: I/O board 12V over recommended voltage.
Knowledge Article: ID B0A037C01: I/O board 12V standby over recommended voltage.
Knowledge Article: ID B0A037C02: 12V standby over recommended voltage
Knowledge Article: ID B0A03CC00: I/O board -5V under recommended voltage.
Knowledge Article: ID B0A03CC00: I/O board -5V over recommended voltage.
Knowledge Article: ID B0A040C00: I/O board 1.5V under recommended voltage.
Knowledge Article: ID B0A040C02: 1.5V standby under recommended voltage
Knowledge Article: ID B0A041C00: I/O board 1.5V over recommended voltage.
Knowledge Article: ID B0A041C02: 1.5V standby over recommended voltage
Knowledge Article: ID B0A07AC00: I/O board 1.8V under recommended voltage.
Knowledge Article: ID B0A07AC02: 1.8V standby under recommended voltage
Knowledge Article: ID B0A07AC00: I/O board 1.8V over recommended voltage.
Knowledge Article: ID B0A07BC02: 1.8V standby over recommended voltage
Knowledge Article: ID B0B026001: Unrecognized Chassis Cooling Device %d
Knowledge Article: ID B0D000281: Expansion card in slot %d is not supported in current BSE configuration.
Knowledge Article: ID B0D01E000: High speed expansion card fault
Knowledge Article: ID B0E006001: Blade %d incompatible with I/O module configuration.
Knowledge Article: ID B0E008001: Blade %d is not responding on the management bus.
Knowledge Article: ID B0E00A001: Blade %d not allowed to power on due to insufficient power.
Knowledge Article: ID B0E00B001: I/O module %d is not allowed to power on due to insufficient power.
Knowledge Article: ID B0E00C001: Blade %d throttled.
Knowledge Article: ID B0E00D001: Storage Module %d is not allowed to power on due to insufficient power.
Knowledge Article: ID B0E00D281: Storage Module %d is not allowed to power on due to insufficient cooling.
Knowledge Article: ID B0E00D381: Storage Module %d reported an early power off event.
Knowledge Article: ID B0E200001: Power denied to blade %d because it has unidentified hardware.
Knowledge Article: ID B0E418802: Expansion Module fault.
Knowledge Article: ID B0E830402: BEM 2.5V over recommended voltage
Knowledge Article: ID B0E830802: BEM 2.5V under recommended voltage
Knowledge Article: ID B0E832402: BEM 3.3V over recommended voltage
Knowledge Article: ID B0E832802: BEM 3.3V under recommended voltage
Knowledge Article: ID B0E834402: BEM 5V over recommended voltage
Knowledge Article: ID B0E834802: BEM 5V under recommended voltage
Knowledge Article: ID B0E836402: BEM 12V over recommended voltage
Knowledge Article: ID B0E836802: BEM 12V under recommended voltage
Knowledge Article: ID B0E83C402: BEM 18V over recommended voltage
Knowledge Article: ID B0E83C802: BEM 18V under recommended voltage
Knowledge Article: ID B0E840402: BEM 1.5V over recommended voltage
Knowledge Article: ID B0E840802: BEM 1.5V under recommended voltage
Knowledge Article: ID B0E840402: BEM 1V over recommended voltage
Knowledge Article: ID B0E840802: BEM 1V under recommended voltage
Knowledge Article: ID B0E860402: BEM 12V standby over recommended voltage
Knowledge Article: ID B0E860802: BEM 12V standby under recommended voltage
Knowledge Article: ID B0E87A402: BEM 1.8V over recommended voltage
Knowledge Article: ID B0E87A802: BEM 1.8V under recommended voltage
Knowledge Article: ID B0EA00001: I/O module %d fault
Knowledge Article: ID B0EA01001: Unable to read VPD for I/O Module %d.
Knowledge Article: ID B0EA05001: I/O module %d in the interposer is not supported in this configuration.
Knowledge Article: ID B0EA0B001: I/O module %d incompatible with other I/O modules
Knowledge Article: ID B0EA0C001: I/O module %d incompatible with blade configuration
Knowledge Article: ID B0EA0C101: I/O module %d incompatible with Storage Module configuration
Knowledge Article: ID B0EA0D001: I/O module %d POST timeout.
Knowledge Article: ID B0EA0D401: Change port link state on I/O module %d failed
Knowledge Article: ID B0EA0D701: Change port speed/mode on I/O module %d failed
Knowledge Article: ID B0EA0D901: Failed to activate firmware image on I/O module %d
Knowledge Article: ID B0EA0E001: I/O module %d POST failure
Knowledge Article: ID B0EA0E101: Active zone pointers
Knowledge Article: ID B0EA0E201: I/O Module %d’s current user defined zone configuration was not
Knowledge Article: ID B0EA0E301: A hard disk drive PFA condition on Storage Module 1 was detected
Knowledge Article: ID B0EA0E501: Battery Backup Unit %d fault condition was detected by I/O Module
Knowledge Article: ID B0EA0E701: I/O Module 01 requires user attention.
Knowledge Article: ID B0EA0E801: Battery Backup Unit %d is not installed for I/O Module
Knowledge Article: ID B0EA0EA01: Drive-Array configuration error was detected by I/O Module %d.
Knowledge Article: ID B0EA0EB01: I/O Modules type mismatch was detected for I/O Modules %d
Knowledge Article: ID B0EA0EC01: I/O Module %d power off request timed-out.
Knowledge Article: ID B0EA0ED01: Unrecognized I/O Module 01 is not allowed to power on.
Knowledge Article: ID B0EA0EE01: A management LAN Communication failure has occurred on I/O Module %d.
Knowledge Article: ID B0EA0E701: An error on I/O Module %d was detected.
Knowledge Article: ID B0EA0F901: A communication failure has occurred on the XML TCP command/response port for I/O Module %d.
Knowledge Article: ID B0EA0FB01: Setting of the active zone configuration number failed for I/O Module %d.
Knowledge Article: ID B0EA0FC01: All zoning has been disabled for I/O Module %d.
Knowledge Article: ID B0EA0FF01: I/O Module %d has no active zone configuration since neither the AMM nor the I/O Module have an active zone configuration.
Knowledge Article: ID B0EA1A401: I/O module %d current fault
Knowledge Article: ID B0EA1C401: I/O module %d temperature fault
Knowledge Article: ID B0EA1D401: I/O module %d over recommended temperature
Knowledge Article: ID B0EC00001: BEM %d fault
Knowledge Article: ID B0EE00000: BSE RAID fault
Knowledge Article: ID B0EE18000: BSE RAID battery failure
Knowledge Article: ID B0F00A001: AMM failed to set the Open Fabric Manager configuration for blade %d
Knowledge Article: ID B0F00B001: Unable to apply Open Fabric Manager configuration to one or more devices at blade %d
Knowledge Article: ID B0F00C001: Blade %d not allowed to power on; constrained by power budget.
Knowledge Article: ID B0F00E001: A device on blade %d does not support Open Fabric Manager
Knowledge Article: ID B0F00F001: Communication problems between an Open Fabric Manager device and a storage target at blade %d
Knowledge Article: ID B1E00E001: Open Fabric Manager configuration mismatch detected between expected configuration and the actual configuration for blade %d
Knowledge Article: ID B1E00F00F: Open Fabric Manager configuration was cleared, because the AMM was moved to a new chassis or restored to default.
Knowledge Article: ID B64001000: Cable on add-in card not connected to system board.
Knowledge Article: ID B6E000001: I/O and Graphics Adapter problem detected.
Knowledge Article: ID B6F100000: The air filter needs service immediately
Knowledge Article: ID B6F200000: The air filter needs service.
Knowledge Article: ID B6F200000: The air filter may need service.
Knowledge Article: ID B6F500000: Routine air filter service check is needed.
Knowledge Article: ID B6F60A101: Alarm Panel module hardware failure.
Knowledge Article: ID B6F60C001: Media Tray %d hardware failure.
Knowledge Article: ID B6F60D001: Multiplexer Expansion module %d communication failed.
Knowledge Article: ID B6F60E002: An error occurred while reading the Control Register of Multiplexer Expansion module %d.
Knowledge Article: ID B6F60F001: Multiplexer Card %d controller firmware was not updated.
Knowledge Article: ID B6F700004: Active volume is inoperable.
Knowledge Article: ID B6F700005: Image file on active volume failed size check and is deleted.
Knowledge Article: ID B6F800101: Storage Module %d removed.
Knowledge Article: ID B6F800201: Storage Module %d fault
Knowledge Article: ID B6F800301: No compatible I/O Module installed for use with Storage Module %d.
Knowledge Article: ID B6F800501: Unable to read VPD for Storage Module %d.
Knowledge Article: ID B6F800601: Storage Module %d may power down due to multiple cooling device failures.
Knowledge Article: ID B6F801201: Storage Module 1 Drive %d fault
Knowledge Article: ID B6F801501: Storage Module 2 Drive %d fault
Knowledge Article: ID B6F802101: Battery Backup Unit %d removed
Knowledge Article: ID B0000006B: Event log full
Knowledge Article: ID B00006011: The battery in Chassis Management Module %s is low.
Knowledge Article: ID B00015503: Chassis Management Module reset because of watchdog timeout
Knowledge Article: ID B00015800: Management bus hang
Knowledge Article: ID B00016015: IP address of primary MM is the same as the IP address of standby MM. Standby network interface is disabled.
Knowledge Article: ID B00016801: Call Home failed
Knowledge Article: ID B00017104: CMM bay location cannot be determined
Knowledge Article: ID B0001D400: Chassis Management Module is over recommended temperature.
Knowledge Article: ID B0001D502: Chassis ambient temperature is over recommended temperature
Knowledge Article: ID B0001D600: Chassis ambient temperature is out of range
Knowledge Article: ID B0001D800: System under recommended ambient temperature
Knowledge Article: ID B00022003: Primary MM real-time clock failed.
Knowledge Article: ID B00022008: Primary CMM Ethernet port failed.
Knowledge Article: ID B0002200A: Primary CMM internal ethernet logical failed.
Knowledge Article: ID B00022015: Standby MM real-time clock failed.
Knowledge Article: ID B00022016: Standby MM local management bus failed.
Knowledge Article: ID B00022019: Standby MM internal I/O logical failed.
Knowledge Article: ID B0002201C: Standby MM external Ethernet port failed.
Knowledge Article: ID B0002201D: Standby MM internal ethernet logical failed.
Knowledge Article: ID B0002201E: Alternate MM communication failed
Knowledge Article: ID B0002205A: Primary MM internal I/O logical failed.
Knowledge Article: ID B00026801: Fan module %s has failed
Knowledge Article: ID B000FF1BA: Cooling zone might not have adequate cooling
Knowledge Article: ID B00038201: Power supply %s transient reading overvoltage
Knowledge Article: ID B00038301: Power supply %s transient reading undervoltage
Knowledge Article: ID B00038401: Power supply %s transient reading overcurrent
Knowledge Article: ID B00038501: Power supply %s power meter is offline
Knowledge Article: ID B00038601: Fan module %s VPD is not valid
Knowledge Article: ID B00038701: Fan logic module %s VPD is not valid
Knowledge Article: ID B00038A01: Power supply %s VPD is not valid
Knowledge Article: ID B00038F01: I/O module %s communication is offline.
Knowledge Article: ID B00039081: The chassis cooling configuration might not be adequate for node %s.
Knowledge Article: ID B00039101: Node %s cannot power on because of insufficient cooling.
Knowledge Article: ID B00039601: Fan module %s VPD is not available
Knowledge Article: ID B00039701: Fan logic module %s VPD is not available
Knowledge Article: ID B00039A01: Power supply %s VPD is not available
Knowledge Article: ID B00038701: Fan logic module %s has failed
Knowledge Article: ID B000A6001: Fan module %s is operating in a degraded state
Knowledge Article: ID B000FF1BA: SMTP server at address is not reachable
Knowledge Article: ID B00217000: Management module external network physical link lost.
Knowledge Article: ID B00217001: Management module external network logical link lost.
Knowledge Article: ID B00222000: Standby MM failure on system management bus, check devices
Knowledge Article: ID B0600A001: Node %s failed initial provisioning.
Knowledge Article: ID B06A2E001: Chassis temperature device is unavailable
Knowledge Article: ID B08028001: Power module %d is off. DC fault.
Knowledge Article: ID B08028481: Power module %d is off. AC fault.
Knowledge Article: ID B08200001: Power module %d communication failure.
Knowledge Article: ID B0821C001: Power module %d has exceeded the warning temperature.
Knowledge Article: ID B0821C081: Power module %d temperature fault.
Knowledge Article: ID B08236001: Power supply %s has shut down because of an overcurrent fault.
Knowledge Article: ID B08236481: Power module %d over voltage fault
Knowledge Article: ID B08236801: Power module %d under voltage fault
Knowledge Article: ID B08526001: Power supply %s encountered an internal fan failure
Knowledge Article: ID B08556001: An internal fan in power supply %s is operating outside the recommended speed.
Knowledge Article: ID B000FF1BA: Chassis front LED card not present
Knowledge Article: ID B000FF1BA: Chassis rear LED card not present
Knowledge Article: ID B0E006001: Node %d incompatible with I/O module configuration.
Knowledge Article: ID B0E008001: Node is not responding on the CMM.
Knowledge Article: ID B0E00A001: Node %d not allowed to power on due to insufficient power.
Knowledge Article: ID B0E00B001: I/O module %d is not allowed to power on due to insufficient power.
Knowledge Article: ID B0E200001: Power denied to node %s because it has unidentified hardware.
Knowledge Article: ID B0EA00001: I/O module %d fault
Knowledge Article: ID B0EA01001: Unable to read VPD for I/O Module %d.
Knowledge Article: ID B0EA0C001: I/O module %d incompatible with node configuration
Knowledge Article: ID B0EA0D001: I/O module %d POST timeout.
Knowledge Article: ID B0EA0E001: I/O module %d POST failure
Knowledge Article: ID B0EA0ED01: Unrecognized I/O Module 01 is not allowed to power on.
Knowledge Article: ID B0EA1A401: I/O module %d current fault
Knowledge Article: ID B0EA1C401: I/O module %d temperature fault
Knowledge Article: ID B0EA1D401: I/O module %d over recommended temperature
Knowledge Article: ID B0EA1F701: I/O module %s is not supported.
Knowledge Article: ID B0F00C001: Node %d not allowed to power on; constrained by power budget.
Knowledge Article: ID B1E00E001: Open Fabric Manager configuration mismatch detected at node %s between the expected configuration and the actual configuration
Knowledge Article: ID B35010411: Security policy is in Pending state at system-management processor on node %s.
Knowledge Article: ID B35010481: Node %s device %s[%s] VPD is not valid.
Knowledge Article: ID B35010801: Unexpected exception affecting node %s was encountered in security service.
Knowledge Article: ID B35010841: Unexpected exception was encountered in security service or system-management processor on node %s
Knowledge Article: ID B35010A00: Unexpected exception was encountered in security service
Knowledge Article: ID B4001711E: The standby CMM failed to synchronize with the primary CMM
Knowledge Article: ID B40040000: Chassis VPD is not valid
Knowledge Article: ID B40040000: Chassis VPD is not available
Knowledge Article: ID B40040101: I/O module %s VPD is not valid.
Knowledge Article: ID B40040201: Chassis Management Module %s VPD is not valid.
Knowledge Article: ID B40040401: Chassis Management Module %s VPD is not available.
Knowledge Article: ID B40050000: Hot air has been detected exiting the rear of the chassis
Knowledge Article: ID B4005001: Chassis Management Module %s is not correctly connected to the chassis.
Knowledge Article: ID B40217009: Standby CMM external network physical link broken
Knowledge Article: ID B4021700A: Standby CMM external network logical link broken
Knowledge Article: ID B40625001: Node %s system-management processor did not complete initialization to allow monitoring.
Knowledge Article: ID B50020000: The Chassis Management Module is not able to communicate with any device.
Knowledge Article: ID B50020101: The Chassis Management Module (CMM) is not able to communicate with the rear LED card.
Knowledge Article: ID B50020201: The Chassis Management Module is not able to communicate with the fan logic module.
Knowledge Article: ID B50020201: The Chassis Management Module is not able to read the vital product data (VPD) on the fan logic module.
Knowledge Article: ID B50020301: I/O module %s communication is offline.
Knowledge Article: ID B50020401: Fan module %s communication is offline
Knowledge Article: ID B50020501: Power supply %s communication is offline.
Knowledge Article: ID B50020601: Node %s communication is offline.
Knowledge Article: ID B77777702: Node %s warning message: %s.
Knowledge Article: ID B77777702: Node %s error message: %s.
Knowledge Article: ID W0010001 – (Windows) IBM Director Platform Agent Services are missing
Knowledge Article: ID W0010002 – (Windows) IBM Director Platform Agent Services failed or are not started
Knowledge Article: ID W0010003 – (Windows) IBM Director Platform Agent Services are incompatible
Knowledge Article: ID W0010004 – (Windows) IBM Director Platform Agent Services return no results for hardware component health queries
Knowledge Article: ID W0020001 – (Windows) The OSA/Avocent IPMI device driver is missing
Knowledge Article: ID W0020002 – (Windows) The OSA/Avocent IPMI driver failed,
Knowledge Article: ID W0020003 – (Windows) The OSA/Avocent IPMI driver is in conflict
Knowledge Article: ID W0030001 – (Windows) IBM IPMI Mapping Layer Missing
Knowledge Article: ID W0030003 – (Windows) IBM IPMI Mapping Layer not needed
Knowledge Article: ID W0040001 – (Windows) The Microsoft IPMI device driver is missing
Knowledge Article: ID W0040002 – (Windows) The Microsoft IPMI driver failed,
Knowledge Article: ID W0040003 – (Windows) Microsoft IPMI Driver In Conflict
Knowledge Article: ID W0050001 – Missing RSA-II Daemon
Knowledge Article: ID W0050002 – RSA-II Daemon failed or is not started
Knowledge Article: ID W0050003 – Incompatible RSA-II Daemon
Knowledge Article: ID W0110001 – (Windows) IBM ServeRAID Manager Agent missing
Knowledge Article: ID W0110002 – (Windows) IBM ServeRAID Manager Agent failed
Knowledge Article: ID W0110003 – (Windows) IBM ServeRAID Manager Agent is in conflict with another component of the system
Knowledge Article: ID W0120001 - (Windows) ServeRAID-MR Provider missing
Knowledge Article: ID W0120002 - (Windows) ServeRAID-MR Provider failed
Knowledge Article: ID W0120003 - (Windows) ServeRAID-MR Provider is in conflict with another component of the system
Knowledge Article: ID X0010001 – The processor is about to fail
Knowledge Article: ID X0010002 – A processor failure was detected during system POST
Knowledge Article: ID X0010010 – A system processor was added or removed
Knowledge Article: ID X0020001 – The DIMM is about to fail
Knowledge Article: ID X0020002 – A DIMM failure was detected during system POST
Knowledge Article: ID X0020010 – System memory added or removed
Knowledge Article: ID X0030001 – A network interface card (NIC) failed
Knowledge Article: ID X0030002 – A network interface card (NIC) is offline
Knowledge Article: ID X0030003 – Teamed NIC switched back to the primary NIC
Knowledge Article: ID X0030004 – Teamed NIC was switched over
Knowledge Article: ID X0030005 – The teamed NIC failed or is back to normal
Knowledge Article: ID X0030010 – The state of the LAN leash on the NIC has changed
Knowledge Article: ID X0040000 – ServeRAID event
Knowledge Article: ID X0050000 - LSI Integrated RAID event
Knowledge Article: ID X0050001 - ServeRAID-MR event
Knowledge Article: ID X0060000 – The health state of the SMART drive (IDE/SCSI) has changed.
Knowledge Article: ID X0060001 – The logical drive is running low on disk space
Knowledge Article: ID X0060002 – The disk drive faulted
Knowledge Article: ID X0060010 – An informational RAID event occured
Knowledge Article: ID X0060011 – An informational ServeRAID event occured
Knowledge Article: ID X0060012 – A RAID health event occurred
Knowledge Article: ID X0090001 – Error detected during Power-On-Self-Test (POST)
Knowledge Article: ID X0090002 – BIOS configuration changed
Knowledge Article: ID X00F0001 – Fan speed is outside the healthy range
Knowledge Article: ID X00F0002 – The revolution speed of an unidentified fan is below the threshold, or normal
Knowledge Article: ID X00P0001 – Power supply failed with possible loss of redundancy
Knowledge Article: ID X00P0002 – Power supply failed
Knowledge Article: ID X00P0003 – Power supply lost AC power with possible loss of standby power
Knowledge Article: ID X00P0010 – Power supply added/removed
Knowledge Article: ID X00S0001 – System Asset ID changed
Knowledge Article: ID X00S0002 – System lease expired
Knowledge Article: ID X00S0003 – System warranty expired
Knowledge Article: ID X00S0004 – Chassis cover opened
Knowledge Article: ID X00T0001 – Enclosure temperarure is out of range
Knowledge Article: ID X00V0001 – Voltage is outside the specified operating range
Knowledge Article: ID X00V0002 – The data for an unidentified voltage sensor is beyond the specified operating range, or within range
Knowledge Article: ID X00X0001 – A hardware component is about to fail
Knowledge Article: ID X00X0002 – A generic hardware event occurred
Knowledge Article: ID X0A00001 – The Service Processor (SP) log has been cleared
Knowledge Article: ID X0A00002 – A new entry has been logged in the Service Processor (SP) error log
Knowledge Article: ID X0A00003 – The Service Processor (SP) error log is full
Knowledge Article: ID X0A10001 – The RSA error log is 75% or 100% full
Knowledge Article: ID X0A10002 – A remote login to RSA has occurred
Knowledge Article: ID X0A20001 – OS hung and restarted
Knowledge Article: ID X0A20002 – IPMI error log 75% full or 100% full
Knowledge Article: ID X0A20003 – BIOS/EUFI needs update for IPMI-compliant management controller
Troubleshooting with System Management software
Downloading System Management software and other software components
Director Clean tool